Sterilization/ Services

 

 

CENTRAL STERLISATION SERVICES DEPARTMENT :
(a)        Exclusive or with substeriliation centres also            :
The following two methods of disinfection and sterilization of the equipment & instruments.
1. Cidex sterilization 2. Autoclave sterilization
The equipments are cleaned, washed and packed in suitable drums. Linen material undergoes autoclaving at 127 degree at 15-20 PSI pressure for 20-25 minutes. Instrument undergoes autoclaving at 127 degree at 15-20 PSI pressure for 20-25 minutes.
(b)        Equipment scope and inservice arrangement           :
Cidex sterilization is used for sharp and heat labile instruments which are kept in Cidex tray for 1 h.
            The Hospital utilizes sterile disposable gloves.
(c)        Volume of work/day    : 60 – 70 drums / day
(a)               Arrangement for sterilization of mattresses & blankets : Mattresses are wrapped with rexin cover which can be washed & cover can be disinfected.            
(b)               Staff available in CSSD :
·         Matron / Head Nurse             : 1
·         Staff Nurses                             : 4
·         Technicians                             : 16
·         Ward boys                               : 8
·         Sweepers                                 : 4
Central sterilization Department :
·         Timings 24 Hours & Shifts: 3 shift of 8 hours each
·         Equipment: Horizontal autoclaves 2 / Vertical autoclaves 2 bowl sterilizer 5 & instrument washing machine & disinfecting _______.
·         ETO Sterilisers / Flash sterilizer (Desirable):
·         No. of Bins 30, Trays 40, Packs sterilized 25/day.                    
· Sterilization validation facilities available:Chemical & microbiological
·         Separate receiving and distribution points:                 Yes
·         staff:    Adequate                                         
    Incharge: Matron
·         Separate 2 autoclave machines for Obst. & Gynac. Dept.